Search found 2 matches


by AllSystemsTechCA
Sat May 14, 2016 5:47 pm
Forum: Jukeboxes
Topic: Seeburg DS 100 pulse amp problem
Replies: 33
Views: 989

Re: Seeburg DS 100 pulse amp problem

I found the reference to the 1.5A in this discussion: https://www.flippers.com/Seeburg-tormat.html I agree that the steady state current I measure is around 30-40mA but it's the surge current from the rapid discharge of that capacitor triggering the toroid flip (detent switch). I'm not disputing tha...
by AllSystemsTechCA
Sat May 14, 2016 3:16 am
Forum: Jukeboxes
Topic: Seeburg DS 100 pulse amp problem
Replies: 33
Views: 989

Re: Seeburg DS 100 pulse amp problem

I have a Seeburg DS160 that I have spent many hours troubleshooting and perhaps some of my journey will help you. I just got it working today! The customer complained of the famous "scans twice" problem and I was determined to fix it. I spent time following the service manual steps and I c...