Problem with DS160 number selection

Q&A about all types of jukeboxes: Wurlitzer, Seeburg, Rock-Ola, AMI, and more.



Topic author
burnt_finger
Regular Member
Posts: 49
Joined: Fri Aug 21, 2015 2:40 pm
Location: Omaha Ne, USA

Re: Problem with DS160 number selection

by burnt_finger » Tue Oct 06, 2015 3:32 pm

Well there was no continuity from pin 28 to common pin 31 so I took the plug apart and I have some good news and some bad news. The good news is the plug looked brand new when I opened it and all the wiring was good, the bad news is the wiring was good.

I am not sure if I will take the TMU apart yet as I want to enjoy what I have at least for a while before I take it out of commission, If/When I take it apart I will update this thread or I just might buy a different one I am not sure what direction I will go yet.

Thanks for all your help
Brad


Ron Rich
Forum Moderator
Posts: 8194
Joined: Sun May 06, 2007 11:31 pm
Location: Millbrae (San Francisco area)CA, USA

Re: Problem with DS160 number selection

by Ron Rich » Tue Oct 06, 2015 3:38 pm

Brad,
Once again--you need not take the TMU apart--yet--didja check the wires at the entrance to the TMU as I described earlier--??
Ron Rich


Topic author
burnt_finger
Regular Member
Posts: 49
Joined: Fri Aug 21, 2015 2:40 pm
Location: Omaha Ne, USA

Re: Problem with DS160 number selection

by burnt_finger » Tue Oct 06, 2015 5:34 pm

Ron,
Yes the TMU was dressed properly (clamped to the mechanism shelf and behind the support post), the clamps where very brittle and I replaced them but it was routed correctly and the TMU wire is in good shape with no kinks in it.

Brad


Ron Rich
Forum Moderator
Posts: 8194
Joined: Sun May 06, 2007 11:31 pm
Location: Millbrae (San Francisco area)CA, USA

Re: Problem with DS160 number selection

by Ron Rich » Tue Oct 06, 2015 6:37 pm

Oh, well--into the TMU you must go--I have a spare TMU--missing the ground bar, but good. PM me if you wish to purchase it.
Ron Rich


Topic author
burnt_finger
Regular Member
Posts: 49
Joined: Fri Aug 21, 2015 2:40 pm
Location: Omaha Ne, USA

Re: Problem with DS160 number selection

by burnt_finger » Wed Oct 07, 2015 1:27 am

Rob/Ron
I figured I had nothing to loose so I took the plung and took the TMU apart. The #28 and #31 common where good all the way back to the Number Circuit 8 so I figured the wire going through the torieds was bad connecting the two. So I got into my pinball stock and took apart a hold coil to get the insulated wire I would need and following the Wiring Diagram I ran it through and hooked it up, had continuity from the plug and after getting everything back together it is selecting all locations!!!! :D :D

Thanks For all your guys help
Brad


Rob-NYC
Senior Member
Posts: 1844
Joined: Sun Sep 25, 2011 3:05 am
Location: Manhattan, NYC USA

Re: Problem with DS160 number selection

by Rob-NYC » Wed Oct 07, 2015 7:34 am

Goof news Brad.
You have joined the elite group who have peered into the "great mysterious Tormat"...and survived.

Rob
"If we believe absurdities, we shall commit atrocities" -- Voltaire