by Ron Rich »
Tue Aug 27, 2013 9:03 pm
Hi James,
Yes--sure, anything CAN be done--however, you then will need to figure out how to put it all back together. IMHO, doing such is un necessary. I remove the unit from the phono, remove the latch bar solenoid ( and meter, on newer ES's), wash it with Ammonia, rinse with HOT water, oil all pivot points and have seldom had further problems, unless one or more of the slides were damaged.
Besides which--the slides and the parts they slid into were silver plated--any "filing" there removes what's left of the plating----
As a general rule, I do not use "contact cleaner" of any nature here. Once in awhile, after checking the action with an analog meter, I find one or more slides that are showing a high resistance. On these "troublesome" ones, I dab just a very small amount of DeoxIT 5 on the slide, and work it in-- Ron Rich