seeburg 222 help

Q&A about all types of jukeboxes: Wurlitzer, Seeburg, Rock-Ola, AMI, and more.



Topic author
ronfil56
Junior Member
Posts: 6
Joined: Sun Mar 14, 2010 12:00 am

seeburg 222 help

by ronfil56 » Sun Mar 14, 2010 12:10 am

Hi everyone. I have a Seeburg 222 with a few issues. First, when I make a selection, the record will get picked up, and then reject immediately. It seems to have something to do with the rear reject button. When I used to push it you would hear a click, and then the record would reject. Now I don't hear anything, and all records reject as soon as they're picked up. Does this sound like a bad switch? Is there a way to bypass the rear reject button so the selections will play. If I do a manual trip the same thing occurs.

Second issue is another strange one. It seems that once the jukebox is on for more than 10 minutes, it stops picking up any selections. It just scans twice, and then returns to the "waiting" position. The 2050 trip tube is lit and seems to be fine. It works fine for the first 3 or 4 selections, then it quits.

Thanks!


Ron Rich
Forum Moderator
Posts: 8194
Joined: Sun May 06, 2007 11:31 pm
Location: Millbrae (San Francisco area)CA, USA

Re: seeburg 222 help

by Ron Rich » Sun Mar 14, 2010 1:49 am

Change the 2050--both problems could be caused by that tube. Then go from there-- Ron Rich


Topic author
ronfil56
Junior Member
Posts: 6
Joined: Sun Mar 14, 2010 12:00 am

Re: seeburg 222 help

by ronfil56 » Sun Mar 14, 2010 3:28 am

Rich,
Replaced both 2050 tubes. Same result. "Instant " reject after selection. No trip after 10 minutes. I'm open to anything at this point. I do have the service manual. Thanks!

Ron


Ron Rich
Forum Moderator
Posts: 8194
Joined: Sun May 06, 2007 11:31 pm
Location: Millbrae (San Francisco area)CA, USA

Re: seeburg 222 help

by Ron Rich » Sun Mar 14, 2010 3:38 am

Ro,
Are you using wall box with that phono?
Pull the 2050's out, scan and detent the phono using the detent release lever--What happens ?
Ron


Topic author
ronfil56
Junior Member
Posts: 6
Joined: Sun Mar 14, 2010 12:00 am

Re: seeburg 222 help

by ronfil56 » Sun Mar 14, 2010 4:26 am

No wall units being used. 2050's have been taken out. Do you mean the trip release lever? I don't see the detent lever in the manual. I see a detent switch, but no lever. Am I missing this? I'm looking on the lower right side of the selector above the reversing switch, to the right. When I use the trip release lever, a trip happens, but again the record instantly rejects.


Ron


Ron Rich
Forum Moderator
Posts: 8194
Joined: Sun May 06, 2007 11:31 pm
Location: Millbrae (San Francisco area)CA, USA

Re: seeburg 222 help

by Ron Rich » Sun Mar 14, 2010 9:05 pm

OK--same lever--different books define it differently-- BTW--remove and leave the upper 2050 out--
You have a "lack of, or lack of proper oil" problem. Look at the first part of the service manual where it describes the mech operation, and the parts section. Look at the "clutch and housing assembly" page, and look for the "clutch member". Now look at the parts book for the same part. The clutch member fork is NOT shown in the first drawing, but is in the parts book. You will need to free that up and re-oil if. Complete instructions are in my "Seeburg Mechanism Guide", available directly from me, by contacting me off list at ronnnrich@yahoo.com Ron Rich


Topic author
ronfil56
Junior Member
Posts: 6
Joined: Sun Mar 14, 2010 12:00 am

Re: seeburg 222 help

by ronfil56 » Mon Mar 15, 2010 3:32 am

Thanks Rich. I'll give it a shot in the next couple of days. If I need your book, I'll e-mail you later this week. Thanks again!!

Who is online

Users browsing this forum: Bing [Bot], Dewey Holcomb, Google Adsense [Bot], Juke-rocks, Scottabs, wcarroll and 7 guests

It is currently Thu Oct 06, 2016 5:11 pm