Seeburg DS160 I have read the net and tried everything i know how to get this problem solved and i cant find the problem . During mech scan i hear a ticking sound out the speakers . When it hits end each side when the reverse switch moves it makes an even louder pop noise . The ticking is louder sometimes and only one direction sometimes , both directions sometimes .
I have removed the tormat and cleaned the contacts and ground strip . I removed and cleaned the detent contacts behind the motor . I have cleaned & checked the best i know how all of contacts on the mech .
I have tested with an ohm meter the mute contact system down to the amp and tested the detent contacts and all the wiring associated with them and all these contacts are working along with the contacts on the reverse switch .
I can pull the cartridge input plug from the amp and that dont work . I checked all the wiring in the amp at the mute socket . I pulled out the 2 lower amp input side tubes and it still pops . During scan using the service switch i noticed the poping ticking is almost gone if i leave the service switch in the middle .
I have adjusted the detent screw during scan . At some point all the ticking noise goes away but then the mech wont pick up any records at all . I put the detent adjustement back and tried sliding the whole tormat side to side . It changes the ticking sound from loud to not so loud . Otherwise it works and sounds just fine .