Page 1 of 1

Seeburg usc 2

Posted: Mon Oct 12, 2015 7:16 pm
by PTL8GRANDKIDS
Hi friends, I'm submitting this question for a friend, so if more information is needed, I will respond back. He is attempting to fix a selection issue. The the #2 will not respond when selected, and #3 comes up when #5 is selected. He says the asm seems ok and he has tried the gray and black boxes. Any questions I will forward to him. thanks--Preston---Syracuse NY..

Re: Seeburg usc 2

Posted: Tue Oct 13, 2015 1:55 am
by Ron Rich
Hi Preston,
I'll bet the 6,7,8 buttons don't work right either--
Data line C is shorted--somewhere--first guess is in the DES-- Are there any DEC' s installed with the phono--?
Does he have a copy pf my "Seeburg MicroLog Trouble Shooting Guide " ?
Ron Rich