I have a K200 AMI and the transformer schematic calls for 3.2a fuse .Installed is a 15a buss tron fuse that is working But I am wondering if this is dangerous to use it.
Having trouble tracking down the correct 3.2a fuse , any alternatives?

thanks Gregg
Prepare your minds for a new scale...of physical scientific values


Rob-NYC
Senior Member
Posts: 1844
Joined: Sun Sep 25, 2011 3:05 am
Location: Manhattan, NYC USA

Re: 3.2A fuse for Ami K200 Alternatives

by Rob-NYC » Mon Aug 17, 2015 5:30 am

That fuse is only for the wallbox supply. 15Amp is way too much. I replace those old fuse holders with a standard AG types as used elsewhere and 4 amp/slo for my locations. If you have only one wallbox, use a 3 amp/slo.

Rob-NYC
"If we believe absurdities, we shall commit atrocities" -- Voltaire


Topic author
ransome
Regular Member
Posts: 36
Joined: Tue Sep 02, 2014 12:10 am
Location: Phoenix Arizona USA 85022

Re: 3.2A fuse for Ami K200 Alternatives

by ransome » Mon Aug 17, 2015 6:35 am

Rob-NYC wrote:That fuse is only for the wallbox supply. 15Amp is way too much. I replace those old fuse holders with a standard AG types as used elsewhere and 4 amp/slo for my locations. If you have only one wallbox, use a 3 amp/slo.

Rob-NYC


Here is a pic , the machine wont select a record if this is not inserted , Does anyone know where to find the 3.2a version?

thanks Gregg

Image
upload a gif

Image
how to screenshot on windows
Prepare your minds for a new scale...of physical scientific values


Topic author
ransome
Regular Member
Posts: 36
Joined: Tue Sep 02, 2014 12:10 am
Location: Phoenix Arizona USA 85022

Re: 3.2A fuse for Ami K200 Alternatives

by ransome » Mon Aug 17, 2015 11:27 am

Nevermind I found one on Needles4jukeboxes.com

thanks anyway
Prepare your minds for a new scale...of physical scientific values


Ron Rich
Forum Moderator
Posts: 8193
Joined: Sun May 06, 2007 11:31 pm
Location: Millbrae (San Francisco area)CA, USA

Re: 3.2A fuse for Ami K200 Alternatives

by Ron Rich » Mon Aug 17, 2015 3:50 pm

Hey Rob,
IMHO, a 4 amp is too high ( it's also illegal !), in that position. A 3.2 is the highest allowed by the national code, and by UL. I use a 1 amp fuse if only one WB is attached. The ONLY reason a fuse bows in that circuit is a short--which rarely happens within a wall-box. Ron Rich


Rob-NYC
Senior Member
Posts: 1844
Joined: Sun Sep 25, 2011 3:05 am
Location: Manhattan, NYC USA

Re: 3.2A fuse for Ami K200 Alternatives

by Rob-NYC » Mon Aug 17, 2015 10:13 pm

Gregg, sorry about the mistake, I saw "K" and immediately thought Seeburg -which does use Fusetrons in some older supply's.

Ron, blown fuses happen in each location at least once year.
Causes (remember, these are 200's)
-Jammed up coins that fall onto the coin switch supply lug as I remove the rejector.
-A-holes that actually force coins into the space between the bottom of the title page support and cover casting and which then work their way into the keyboard causing the same effect as below:
-A small piece of copper spring metal that breaks off the keyboard assembly and works it's way into a position where it bridges the "singles -EP" terminals in the keyboard itself and thus causes a direct short at the credit cancel point. This needn't be the case, but Seeburg made the wiring excessively complicated. It took me hours to finally track down this cause, but at least I don't have to swap out boxes any more when it happens. I disconnect them, unmount and shake upside down & sideways till something falls out.

-Backed up coins that jam the coin switch and burn out the coin coil. The coils are quite rugged, but I have has two that shorted. Lately I have been adding fuses in each box.

-Cancel-override contacts on the lower cam that weld together and produce a dead short. Again, a stupid Seeburg design. There is no good reason for this setup.

I don't know how you can use a 1 amp fuse on boxes where each draws 2-½ sending (3Wa's) and spikes at 3 amp during credit cancel. On -one 3W1- with no lights and a delay fuse -maybe.

You have better luck with fuses than I do :-)

Rob