Page 1 of 1

Rowe ami RI-1G

Posted: Fri Dec 25, 2015 8:05 pm
by clones
Hi
Had a strange problem with this machine. It selected but tone arm cut off won't reject the first record it happened to and the turntable has stopped and the cancel button won't work either.
Funny thing about it you can actually make a selection and record basket will revolve and a record will be transferred but off course the tone arm and previous record are there but if the tone arm is moved across to cut off point the gripper will return that record but turntable still doesn't move
Any ideas
Clones

Re: Rowe ami RI-1G

Posted: Fri Dec 25, 2015 9:12 pm
by clones
Hi
Just an update turntable now working ,wasn't seated properly. The tone arm is not going back to its home position after play all other elements of selection,transfer and return of record seem OK
Any common problems with Rowe Amis re tone arm binding etc
Clones

Re: Rowe ami RI-1G

Posted: Fri Dec 25, 2015 10:05 pm
by Ron Rich
Hi Clones,
I am not familiar with that model AMi-- IF, the tone arm lifts straight up, try the following:
Play a selection --allow the record to land fully on the turn table, LIFT the tone are from it's BASE, and place it onto the record start grooves.
It should now play the record and "reject" it at the end-
Ron Rich

Re: Rowe ami RI-1G

Posted: Sat Dec 26, 2015 2:40 am
by clones
Thanks Ron Happy Christmas and to all on phonoland
clones

Re: Rowe ami RI-1G

Posted: Tue Dec 29, 2015 2:19 am
by clones
Hi Ron
yes your suggestion sorted it out and its playing fine now
regards
clones