Preston, this is one of the quirks of both the 2050 and that particular circuit.
If the tube is marginal, the cathode will be 'excited" by being made to conduct, in this case it is by a long train of pulses.
The large 5mfd cap is another typical failure point which can cause erratic miscounts.
If the small sets of contacts that ride the letter stepper clapper are not making reliably the transfer relay or the hold magnet will not be energized. Similarly, the time constant capacitor for the hold magnet must be good or the hold magnet will jitter and fall out during the transfer interval.
If contacts on the two timing relays are not in good condition, this same symptoms you describe will occur.
The first step is to remove the stepper cover and observe the step wheels in operation.
Rob/NYC