Receiver (WSR7-L6) re-capped, transformer secondary voltages previously tested and within specs. Continuing to test receiver (amp not connected, pin bank not attached) using a dim bulb test lamp. I have a 3/4 amp slo-blo fuse installed for testing in place of the 5 amp fuse.
Installed 2050 tube, tube lit up, no issue, test bulb remained dim. Plugged in mech, no issues, popularity meter light lit up, test bulb remained dim. Installed plug for service switch, switch in center position, no issue. Moved switch to right, no issue. Moved switch to left briefly, play control relay energized, popularity meter light went dim, dim bulb test light went bright. Motor did not turn in any service switch position. Motor did scan in both directions when powered directly through reversing switch. Did not test receiver further.
Should I have expected the motor to turn using the service switch? Does the bright test bulb indicate a problem when the control relay energized? Would the test bulb have slowly dimmed?
Thanks.