STOP--right there--do not replace that 15 amp fuse with another 15 amp fuse !!!
If there was still a 15 amp fuse in that hole, it should have been changed to a 7.5 MAX, years ago. I usually put a 7 in that spot--I strongly suggest that you not install any value fuse till you track down the reason it blew--it is the "24vac circuit"--and if trouble shot by installing multiple fuses, WILL cause major damage.
The most common reason for that fuse "blowing" is a shorted trip coil--
I also would suggest that you contact me off forum, and purchase a copy of my "Seeburg Microlog Trouble Shooting Guide", and read it before going any further---