Hi
I am trying to hook up a WRE wallbox to my R83 but with no luck,the WRE seems to have one wire less noted as clock on jukebox,Is it possible to hook up a WRE instead of a WRD to a R83? What does clock really mean? thanks in advance


ami-man
Forum Moderator
Posts: 984
Joined: Mon Apr 24, 2006 3:43 pm
Location: Sheffield UK

Re: Rowe Wallbox WRE Hookup for R83

by ami-man » Mon Jun 20, 2011 11:40 am

Hello mobileman,

Not sure re the wre wallbox, but you need the following interface or code converter to operate with WRA, WRC and WRD, it is a 201-15336-06.
There was also a 2-66934-05 code converter to work with a Seeburg 160 digital wallbox.

Regards
Alan Hood