by Old Goat » Sat Oct 10, 2015 2:22 am
by Rob-NYC » Sat Oct 10, 2015 6:16 am
by Old Goat » Sat Oct 10, 2015 3:56 pm
by Ron Rich » Sat Oct 10, 2015 4:37 pm
by Old Goat » Sun Oct 11, 2015 5:05 pm
Ron Rich wrote:Hi Goat--
Just curious--why don't you contact "Bill" about this ??
Ron Rich
by Ron Rich » Sun Oct 11, 2015 6:50 pm
by Rob-NYC » Sun Oct 11, 2015 11:03 pm
by Old Goat » Thu Oct 15, 2015 3:17 am
Rob-NYC wrote:Brooks, if the AGC was completely removed as you describe, there should not be anything to cause volume variation. What level comes up at first should stay and not go down. So, if at all possible, try replacing the small tubes on the board.. One may be gassy or have a hot spot.
Rob
by MattTech » Thu Oct 15, 2015 6:14 am
by Old Goat » Thu Oct 15, 2015 2:48 pm
MattTech wrote:When the need arises, I replace the tubes in my customer's sets with N.O.S. replacements.
They may cost a bit more, but I tend to find that in numerous occasions they perform better, tolerate abuse better, and eliminate callbacks.
RCA, GE, Sylvania, etc... all can't be beat.
by Ron Rich » Thu Oct 15, 2015 6:15 pm